Product Data Sheet
SD 4100-2E04
September 2011
Damcos
®
VPI total programme
VPI - Valve Position Indicator
The Volumetric Position Indicator type VPI is de-
signed to locally and remotely indicate the position of
hydraulically operated Actuators.
The VPI can be placed with the directional valve on
a common manifold remote from the Actuator, thus
avoiding cables and direct mounted installations
in the eld and the costs involved. In this way the
problems are overcome as to detecting the valve
position, when the Actuator is submerged and/or
installed in Hazardous Area.
The VPI continuously indicates the position of the
valve by measuring the actual quantity of oil owing
to or from its Actuator.
The VPI is preset to match the specic Actuator dis-
placement. The rendered indication is proportional
to the displaced oil and thus to the actual actuator
position.
The total VPI programme includes pressure and
temperature compensation, and the programme is
designed for solving indication purposes in any en-
vironment. The VPI programme is designed for use
with standard CETOP-3 components.
When using the VPI there are some simple rules
regarding the valve control, which must be followed
in order to obtain the optimal position indication. For
further information please contact Emerson Process
Management, MTM.
General description
2
Product Data Sheet
SD 4100-2E04
September 2011
Damcos
®
VPI total programme
PTC-Block:
Technical specications
Max. working pressure: 135 bar ~ 1958 lbf/in
2
Test pressure: 225 bar ~ 2973 Ibf/in
2
Burst pressure: > 525 bar ~ 7615 Ibf/in
2
Temperature range: -20°C to 80°C ~ 4°F to 176°F
Viscosity range: 15-200cSt
Filtration requirement: 25 μm nominal
Hydraulic medium: Acid-free hydraulic oil
Max. ow: 100 cm
3
/sec ~ 6 l/min
Min. ow: 3 cm
3
/sec ~ 0.2 l/min
Connection face: DIN 24340 Cetop 3/VPI connection
Total programme
Temperature compensating block for indication of
end positions (VPI-V and -E). The TC-Block allows
the compression/decompression of the oil in the
system caused by major temperature and pressure
variations,
TC-Block:
Pressure and temperature compensating block pri-
marily for analog indication (VPI-C). The PTC-Block
allows the compression/decompression of the oil in
the system caused by major temperature and pres-
sure variations, without inuencing the indicator, and
without inuencing the indicator and ensures xed
electrical on/off remote ind. signal. The TC-Block is
provided with CETOP-3 connection for mounting of
pilot valve (4/2 way).
ensures precise intermediate positions, as the
positioning is always made at constant pressure (5
bar). The PTC-Block is provided with CETOP-3 con-
nection for mounting of solenoid pilot valve (4/3 way
spring center).
Basically the valve position indicator is a precision
gear motor with a display indicating the ow of a
certain oil volume through the unit. The gear wheels
rotate according to ow and ow direction of the
uid. A built-in mini gear box with a gear ratio chosen
to suit the actuator displacement in question trans-
fers the gear motor movement to the indicator shaft.
There is no mechanical connection between the gear
motor and the indicator shaft. The rotary movement
of the hydraulic gear wheels is transferred to the
indicator shaft by a magnetic clutch.
Product Data Sheet
SD 4100-2E04
September 2011
Damcos
®
VPI total programme
The Emerson logo is a trademark and service mark of Emerson Electric Co. Damcos
®
and the Damcos logotype are registered trademarks of
Damcos A/S. All rights reserved. The contents of this publication are presented for information purposes only, and while effort has been made
to ensure their accuracy, they are not to be construed as warranties or guarantees, expressed or implied, regarding the products or services
described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve
the right to modify or improve the designs and specications of our products at any time without notice. Damcos A/S accepts no responsibility
for any errors that may appear in this publication.
This product is developed and managed by:
Emerson Process Management
Damcos A/S
Aaderupvej 41
DK-4700 Naestved
T +45 5578 7200
F +45 5578 7272
For global contacts:
www.EmersonProcess.com/mtm
© 2008 Damcos A/S
Commonly used combinations:
1. VPI-V-TC ~ Visual indication.
2. VPI-E-TC ~ Electrical/visual on/off indication.
3. VPI-C-PTC ~ Electrical/visual analog indication.
Commonly used combinations
Top part
Bottom part
Blocks
Control valves
Solenoid valve
4/3 way
Solenoid valve
4/2 way
- V
- E
- C
The VPI always consists of a VPI top part, a VPI bot-
tom part and a VPI compensator block (TC or PTC).